3” & 4” Flange Heaters - Incoloy Sheath
C4
50-60 watts/in
2
Incoloy Sheath T
ypically to heat:
150 psi steel flange - ANSI rated municipal water
4
cold section process water
Up to 600 volts (specifiy voltage and 1 or 3 phase when ordering)
kw immersed net
length catalogue number weight
B dim. (lb)
4.5 14 PFIH-3-03004 13
6.0 18 PFIH-3-03006 14
7.5 19 PFIH-3-03007 14
9.0 25 PFIH-3-03009 15
10.5
28 PFIH-3-03010 16
12.0
32 PFIH-3-03012 16
15.0 39 PFIH-3-03015 18
18.0 47 PFIH-3-03018 19
22.5 54 PFIH-3-03022 20
3”
- 150 psi flange, 3 elements in flange
kw immersed net
length catalogue number weight
B dim. (lb)
9 14 PFIH-3-06009 16
12 18 PFIH-3-06012 17
15 19 PFIH-3-06015 17
18 25 PFIH-3-06018 18
21 28 PFIH-3-06021 19
24 32 PFIH-3-06024 19
30 39 PFIH-3-06030 21
36 47 PFIH-3-06036 22
45 54 PFIH-3-06045 23
3” - 150 psi flange, 6 elements in flange
kw immersed net
length catalogue number weight
B dim. (lb)
13.5 14 PFIH-4-09013 18
18.0 18 PFIH-4-09018 19
22.5 19 PFIH-4-09022 19
27.0 25 PFIH-4-09027 20
31.5 28 PFIH-4-09031 21
36.0 32 PFIH-4-09036 21
45.0 39 PFIH-4-09045 23
54.0 47 PFIH-4-09054 24
67.5 54 PFIH-4-09067 25
3
11
/
16
"
5
13
/
16
"
5
1
/
4
"
3"
Figure 117
5
5
/
8
"
11
5
/
8
"
3
11
/
16
"
5
1
/
4
"
4
1
/
4
"
2"
Figure 116
5
5
/
8
"
6
1
/
2
"
Figure 119
4
5
/
8
"
15
/
16
"
4
5
/
8
"
7
1
/
2
"
4“
Col
d
Section
Figure 115
3” 150# ANSI flange heater
S
tandard terminal box
4
5
/
8
"
15
/
16
"
5
1
/
2
"
9"
4“
Col
d
Sec
tion
Figure 118
4” 150# ANSI flange heater
Standard terminal box
Moisture Resistant terminal enclosure
(suffix MR
) Type 4 / NEMA 4
Moisture Resistant terminal enclosure
(suffix MR
) Type 4 / NEMA 4
Hazardous Location
(E
xplosion Resistant suffix ER)
Type 4 / NEMA 7
Hazardous Location
(Explosion Resistant suffix ER)
Type 4 / NEMA 7
kw immersed net
length catalogue number weight
B dim. (lb)
9 14 PFIH-4-06009 13
12 18 PFIH-4-06012 14
15 19 PFIH-4-06015 14
18 25 PFIH-4-06018 15
21 28 PFIH-4-06021 16
24 32 PFIH-4-06024 16
30 39 PFIH-4-06030 18
36 47 PFIH-4-06036 19
45 54 PFIH-4-06045 20
4” - 150 psi flange, 6 elements in flange
4” - 150 psi flange, 9 elements in flange
Figure 120
3” Flange 3 Elements
3
Flange 6 Elements